SAP calculations are required for every new-build dwelling in the UK to generate an Energy Performance Certificate. The Standard Assessment Procedure (SAP) is the government’s official methodology for rating dwelling energy performance, estimating annual energy use, carbon emissions, and running costs based on design, materials, and installed systems.
Without a compliant SAP assessment and Energy Performance Certificate (EPC), it is illegal to sell or rent any dwelling—making these calculations essential for every new construction project. This guide covers new-build SAP only (Part L1A SAP), not conversions or extensions, which use different L1B calculations.
For a comprehensive overview of all SAP calculation types and requirements, see our complete SAP Calculations Guide.

When You Need SAP Calculations for New Builds
SAP calculations for new builds are legally required to demonstrate compliance with Part L1A of the Building Regulations in England and Wales (Section 6 in Scotland, Part F1 in Northern Ireland). Every new dwelling must have both a compliant SAP assessment and an official EPC before it can be sold or rented.
The assessment must occur in two mandatory stages:
- Design-stage assessment before construction begins
- As-built assessment after construction completion
Both stages require qualified, accredited energy assessors and must be submitted to Building Control for approval.
The Two-Stage SAP Process
Design-Stage Assessment (Pre-Construction)
Arrange your design-stage SAP calculations for new builds as early as possible in the building process. Changes are significantly cheaper and easier to implement on paper rather than during construction.
The assessor analyses proposed building plans, specifications, and construction details using approved SAP software. This desktop assessment requires no site visits, working from architectural drawings, construction specifications, and building services design.
The process produces a Predicted Energy Assessment (PEA) with provisional compliance results and EPC rating. If the design fails to meet regulatory targets, the assessor recommends specific improvements—additional insulation, upgraded glazing, more efficient heating systems, or renewable energy installations.
Once the design achieves compliance, the assessor issues the SAP compliance report and submits it to Building Control demonstrating Part L compliance before construction begins.
As-Built Assessment (Post-Construction)
After construction completion and mandatory airtightness testing, the assessor updates the SAP model with actual built data. This includes measured air leakage rates and final installed equipment specifications (exact boiler models, controls, renewable systems).
The final calculation produces the as-built SAP report and official Energy Performance Certificate reflecting any construction deviations. Building Control requires both documents for completion sign-off—no final approval is granted without compliant SAP calculations for new builds.
Understanding Your SAP Calculations for New Builds Results
SAP calculations for new builds focus on key compliance indicators that determine whether your building meets regulatory standards. These targets are derived from a “notional dwelling” – a standardized reference building of identical size and shape to your proposed dwelling, but built to minimum Part L specification standards. This notional dwelling establishes the performance benchmarks that your actual building must meet or exceed.
The three mandatory compliance metrics are:
- Dwelling Emission Rate (DER): Your dwelling’s actual annual CO₂ emissions
- Target Emission Rate (TER): Maximum permitted CO₂ emissions for the notional dwelling
- Dwelling Fabric Energy Efficiency (DFEE): Your building’s actual heat loss through walls, windows, roof, and floors
- Target Fabric Energy Efficiency (TFEE): Maximum permitted fabric heat loss for the notional dwelling
- Dwelling Primary Energy Rate (DPER): Your building’s total primary energy consumption
- Target Primary Energy Rate (TPER): Maximum permitted primary energy consumption for the notional dwelling
Your dwelling passes compliance when DER ≤ TER, DFEE ≤ TFEE, AND DPER ≤ TPER—all three tests must be satisfied simultaneously.
The SAP also produces a numerical score from 1 to 100+ (higher indicates greater efficiency), with a score of 100 representing net-zero energy cost. This SAP score translates directly to your EPC efficiency rating:
- 92-100+: EPC Rating A
- 81-91: EPC Rating B
- 69-80: EPC Rating C
- 55-68: EPC Rating D
- 39-54: EPC Rating E
- 21-38: EPC Rating F
- 1-20: EPC Rating G
Higher ratings mean lower energy bills and carbon emissions, with A-rated properties being the most energy efficient.
What Information You Need to Provide
Comprehensive data ensures accurate SAP calculations for new builds results and avoids conservative software assumptions that may impact your score:
Architectural Plans and Specifications:
- Floor plans, elevations, sections, and site plans showing orientation
- Dimensions, materials, and construction types
Construction Details:
- Wall, floor, and roof build-ups including insulation materials and thicknesses
- U-values where available
Windows and Doors:
- Sizes, types, glazing, frames, and performance ratings
- U-values representing heat loss rates through openings
Heating and Hot Water Systems:
- Types of boilers or heat pumps, fuel source, controls, and efficiency ratings
Ventilation Systems:
- Mechanical or natural ventilation details, including any heat recovery systems
Renewable Energy Installations:
- Details of solar PV, solar thermal, heat pumps, or other renewables, including capacities and controls
Additional Requirements:
- Airtightness strategy or target levels
- Types and efficiency of fixed lighting installations
- Thermal bridging schemes for construction junctions

What SAP Calculations for New Builds Analyse
SAP calculations for new builds provide comprehensive analysis across multiple building performance areas:
Building Fabric Performance: Insulation levels with accurate U-values, window and door specifications including solar gain values, thermal bridging at construction junctions, and overall building airtightness.
Heating, Ventilation, and Cooling Systems: Heating system efficiency, heating controls such as smart thermostats and zoning systems, ventilation systems and heat recovery technologies, and air conditioning systems where installed.
Energy Consumption Factors: Lighting systems including LED technologies and automated controls, water heating system efficiency, renewable energy installations, and building dimensions, orientation, and solar gains.
Additional Performance Metrics: Air leakage rates measured through mandatory airtightness testing, mechanical and electrical system specifications, and fuel types used for space heating, water heating, lighting, and ventilation.
Essential Documentation You’ll Receive
SAP calculations for new builds generate several documents required by Building Control:
Design-Stage Documents:
- Predicted Energy Performance Certificate (Predicted EPC)
- SAP compliance report with calculated DER/DFEE/DPER values
- Building Regulations Emissions Leaflet (BREL)
- Part L compliance pack with thermal bridging and U-value certificates
Completion-Stage Documents:
- As-built SAP report reflecting measured construction data
- Final Energy Performance Certificate (EPC) with official efficiency rating
- Updated BREL confirming continued compliance
All documentation must be submitted to Building Control, with the final EPC being a legal requirement for every newly built dwelling. Final EPCs remain valid for 10 years from the date of issue.
Choosing the Right SAP Assessor
SAP calculations for new builds must be performed by accredited energy assessors registered with official schemes such as Elmhurst or Quidos. Choose assessors based on:
Essential Qualifications:
- Full accreditation under recognized assessment schemes
- Extensive new build experience and Part L expertise
- Proven track record with similar project types and sizes
Service Quality:
- Consultative approach explaining implications of design choices
- Clear communication translating technical concepts for non-specialists
- Collaborative working with architects, engineers, and contractors
- Responsive service aligned with project timelines
Value-Added Services:
- Proactive solution recommendations for failing assessments
- Access to accredited thermal bridging details and U-value data
- Building Control liaison and submission support
- Guidance on renewable energy integration and planning requirements
Typical single-house SAP reports complete within several days, though complex projects require longer timeframes. Our SAP calculations are available starting from £99.
Common Mistakes to Avoid
Underestimating insulation needs: Proper insulation is essential for achieving a good SAP score. Failing to account for high-quality insulation materials in the design phase can lead to higher energy consumption.
Overlooking ventilation systems: While a well-sealed building minimises air loss, it must also have adequate ventilation to avoid condensation and other issues. Balanced ventilation with heat recovery is often necessary.
Poor window and door specifications: Windows and doors should have low U-values to minimise heat loss. This is often an area where small improvements can make a significant difference to overall energy performance.
Delaying SAP calculations: Waiting until the end of the build to conduct SAP calculations for new builds can be costly. Involving SAP assessors early in the design phase will help avoid expensive retrofits later.
Benefits of Early SAP Calculations for New Builds Integration
Design Optimization: Early SAP calculations for new builds enable informed decisions about building orientation, material selection, and system specifications that optimize energy performance from project inception.
Cost Control: Strategic investments identified through SAP analysis provide maximum return on investment through reduced long-term energy bills, while avoiding expensive late-stage design changes.
Risk Mitigation: Early compliance verification prevents costly construction delays, redesigns, or non-compliance penalties by identifying issues while solutions remain cost-effective.
Market Competitiveness: High EPC ratings attract buyers and tenants, potentially commanding premium sale prices or rental income while demonstrating responsible development practices.
Regulatory Compliance: SAP calculations for new builds ensure adherence to local planning policies and building regulations across all UK jurisdictions.
Maximizing Your SAP Performance
Achieving optimal SAP scores requires strategic design decisions informed by early assessment. High-performing new builds typically feature:
- Enhanced insulation levels exceeding minimum requirements
- High-efficiency heating systems with smart controls
- Triple-glazed windows with low U-values and optimal solar gain
- Integrated renewable energy systems
- Superior airtightness through quality construction practices
- Minimized thermal bridging through careful junction design
The outcome of comprehensive SAP calculations for new builds analysis is a compliant, energy-efficient building with lower operating costs and enhanced market appeal.
Current Standards and Future Developments
SAP 10.2, released in 2022, represents the current official methodology for all new build assessments. However, the UK government is developing the new Home Energy Model to replace SAP alongside the Future Homes Standard implementation around 2025.
Despite upcoming changes, SAP calculations for new builds remain mandatory under current regulations. Early engagement with qualified assessors ensures your project benefits from the latest technical guidance while maintaining compliance with evolving standards.
Conclusion
By following proper SAP calculations for new builds procedures—providing detailed design information, engaging qualified assessors early, and implementing recommended improvements—builders ensure their new dwellings exceed current energy standards while future-proofing against increasingly stringent requirements.